IRTUM – Institutional Repository of the Technical University of Moldova

Influence of CuO nanostructures morphology on hydrogen gas sensing performances

Show simple item record

dc.contributor.author LUPAN, O.
dc.contributor.author POSTICA, V.
dc.contributor.author ABABII, N.
dc.contributor.author HOPPE, M.
dc.contributor.author CRETU, V.
dc.contributor.author TIGINYANU, I.
dc.contributor.author SONTEA, V.
dc.contributor.author PAUPORTÉ, Th.
dc.contributor.author VIANA, B.
dc.contributor.author ADELUNG, R.
dc.date.accessioned 2020-05-21T10:06:49Z
dc.date.available 2020-05-21T10:06:49Z
dc.date.issued 2016
dc.identifier.citation LUPAN, O., POSTICA, V., ABABII, N. et al. Influence of CuO nanostructures morphology on hydrogen gas sensing performances. In: Microelectronic Engineering. 2016, vol. 164, pp. 63-70. ISSN 0167-9317. en_US
dc.identifier.issn 0167-9317
dc.identifier.uri https://doi.org/10.1016/j.mee.2016.07.008
dc.identifier.uri http://repository.utm.md/handle/5014/8311
dc.description Access full text - https://doi.org/10.1016/j.mee.2016.07.008 en_US
dc.description.abstract In this study, the impact of different morphologies of p-type copper oxide nanostructures on hydrogen gas response is investigated. Sensor structures based on CuO nanowire (NW) networks demonstrated much higher gas response (~340) than nanostructured films (~3) at operating temperatures of 300°C. Such a high gas response in the case of CuO NW networks is explained by percolating phase transition of CuO NW surface to metallic Cu. The phenomenon is observed at operating temperatures higher than 275°C, but show good reversibility at 300°C. At a higher operating temperature of 400°C, the gas response was found lower (~108) than at 300°C, even if the response time and percolating time were much shorter. On the other hand, the faster recovery time (~2s) to the initial value of electrical baseline was observed at an operating temperature of 300°C. This latter temperature is found the best regime for stable and highly sensitive and selective detection of hydrogen with high repeatability for sensor structures based on CuO NW networks. These results will help to take full advantage of these functional nanomaterials in the new generation of sensorial nanodevices for their larger scale utilization. en_US
dc.language.iso ro en_US
dc.publisher ELSEVIER en_US
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject nanowires en_US
dc.subject sensing mechanisms en_US
dc.subject hydrogen en_US
dc.subject percolating en_US
dc.subject metallization en_US
dc.title Influence of CuO nanostructures morphology on hydrogen gas sensing performances en_US
dc.type Article en_US


Files in this item

The following license files are associated with this item:

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 United States Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 United States

Search DSpace


Browse

My Account