IRTUM – Institutional Repository of the Technical University of Moldova

Measurements of dichroic bow-tie antenna arrays with integrated cold-electron bolometers using YBCO oscillators

Show simple item record

dc.contributor.author REVIN, Leonid S.
dc.contributor.author PIMANOV, Dmitry A.
dc.contributor.author CHIGINEV, Alexander V.
dc.contributor.author BLAGODATKIN, Anton V.
dc.contributor.author ZBROZHEK, Viktor O.
dc.contributor.author SAMARTSEV, Andrey V.
dc.contributor.author ORLOVA, Anastasia N.
dc.contributor.author MASTEROV, Dmitry V.
dc.contributor.author PARAFIN, Alexey E.
dc.contributor.author SAFONOVA, Victoria Yu.
dc.contributor.author GORDEEVA, Anna V.
dc.contributor.author PANKRATOV, Andrey L.
dc.contributor.author KUZMIN, Leonid S.
dc.contributor.author SIDORENKO, Anatolie S.
dc.contributor.author MASI, Silvia
dc.contributor.author BERNARDIS, Paolo de
dc.date.accessioned 2024-06-12T07:09:55Z
dc.date.available 2024-06-12T07:09:55Z
dc.date.issued 2024
dc.identifier.citation REVIN, Leonid S. et al. Measurements of dichroic bow-tie antenna arrays with integrated cold-electron bolometers using YBCO oscillators. In: Beilstein Journal of Nanotechnology, 2024, vol. 15, pp. 26-36. ISSN 2190-4286. en_US
dc.identifier.issn 2190-4286
dc.identifier.uri https://doi.org/10.3762/bjnano.15.3
dc.identifier.uri http://repository.utm.md/handle/5014/27361
dc.description Acces full text - https://doi.org/10.3762/bjnano.15.3 en_US
dc.description.abstract We consider properties of dichroic antenna arrays on a silicon substrate with integrated cold-electron bolometers to detect radiation at frequencies of 210 and 240 GHz. This frequency range is widely used in cosmic microwave background experiments in space, balloon, and ground-based missions such as BICEP Array, LSPE, LiteBIRD, QUBIC, Simons Observatory, and AliCPT. As a direct radiation detector, we use cold-electron bolometers, which have high sensitivity and a wide operating frequency range, as well as immunity to spurious cosmic rays. Their other advantages are the compact size of the order of a few micrometers and the effect of direct electron cooling, which can improve sensitivity in typical closed-loop cycle 3He cryostats for space applications. We study a novel concept of cold-electron bolometers with two SIN tunnel junctions and one SN contact. The amplitude–frequency characteristics measured with YBCO Josephson Junction oscillators show narrow peaks at 205 GHz for the 210 GHz array and at 225 GHz for the 240 GHz array; the separation of these two frequency bands is clearly visible. The noise equivalent power level at an operating point in the current bias mode is 5 × 10−16 W/√Hz. en_US
dc.language.iso en en_US
dc.publisher Beilstein Institut en_US
dc.relation.ispartofseries Beilstein Journal of Nanotechnology;2024, vol. 15
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject dichroic antenna arrays en_US
dc.subject cold-electron bolometers en_US
dc.subject cosmic microwave background en_US
dc.subject dichroic antenna arrays en_US
dc.subject dipole bow-tie antenna en_US
dc.subject Josephson junction en_US
dc.title Measurements of dichroic bow-tie antenna arrays with integrated cold-electron bolometers using YBCO oscillators en_US
dc.type Article en_US


Files in this item

The following license files are associated with this item:

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 United States Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 United States

Search DSpace


Browse

My Account