dc.identifier.citation MURDID, Ecaterina, BORIS, Jingan, DOBREA, Ina et al. Influence of Synchronized Measurement Errors on the Results of Identification of the Transmission Line Parameters. In: Annals of the University of Craiova, Electrical Engineering ser., 2020, N. 44, Iss. 1, pp. 14-19. ISSN 1842-4805. en_US
dc.identifier.issn 1842-4805
dc.identifier.uri http://repository.utm.md/handle/5014/19010
dc.description.abstract The parameters of transmission lines, as a rule, are determined by reference data, but during the operation, it might vary essentially from the actual data. There are noted the reasons for the parameters’ modification. This paper explains the opportunity of parameter identification based on the synchronized measurements during the operation of the transmission line. The methods of parameter identification can be classified by various criteria. The diagram of classification was elaborated for the first time. Transmission lines can be represented in the form of quadripole and the Т- and П-forms equivalent schemes, so, applying only the current and voltage synchronized measurement on both ends it is possible to obtain passive parameters of the line. There are presented final formula of six most effective methods for parameter identification of the transmission lines. All analyzed methods were verified with the models of real transmission line. There were compared the results of all proposed methods: the relative errors of calculation for all mentioned methods are less than 1%. The obtained results show the high accuracy of parameter identification for the proposed methods. The influence of measurement errors upon the values of parameters’ results was analyzed in this work. The main contribution of this paper lies in the classification of the methods of transmission line parameters identification and in the research of influence of measurement errors on the results of the parameter identification for transmission lines. en_US
dc.language.iso en en_US
dc.publisher University of Craiova en_US
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject linii electrice en_US
dc.subject măsurări sincronizate en_US
dc.subject scheme echivalente en_US
dc.subject cuadripoli en_US
dc.subject curenți en_US
dc.subject transmission lines en_US
dc.subject synchronized measurements en_US
dc.subject equivalent circuits en_US
dc.subject circuits en_US
dc.subject quadripole coefficients en_US
dc.subject currents balance en_US
dc.subject powers balance en_US
dc.title Influence of Synchronized Measurement Errors on the Results of Identification of the Transmission Line Parameters en_US
dc.title.alternative Influence of Synchronized Measurement Errors on the Results of Identification of the Transmission Line Parameters en_US
dc.type Article en_US


Files in this item

The following license files are associated with this item:

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 United States Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 United States

Search DSpace


Browse

My Account