IRTUM – Institutional Repository of the Technical University of Moldova

Telemetric system for monitoring the parameters of an experimental stand for tracking the damaging effects of penetrating wounds

Show simple item record

dc.contributor.advisor KOLISNYK, Kostiantyn
dc.contributor.author ZAIATS, Dmytro
dc.contributor.author KOLISNYK, Kostiantyn
dc.contributor.author SHYSHKIN, Mykhailo
dc.date.accessioned 2024-10-15T07:03:32Z
dc.date.available 2024-10-15T07:03:32Z
dc.date.issued 2024
dc.identifier.citation ZAIATS, Dmytro; KOLISNYK, Kostiantyn and Mykhailo SHYSHKIN. Telemetric system for monitoring the parameters of an experimental stand for tracking the damaging effects of penetrating wounds. In: Conferinţa tehnico-ştiinţifică a studenţilor, masteranzilor şi doctoranzilor = Technical Scientific Conference of Undergraduate, Master and PhD Students, Universitatea Tehnică a Moldovei, 27-29 martie 2024. Chișinău, 2024, vol. 2, pp. 963-967. ISBN 978-9975-64-458-7, ISBN 978 9975-64-460-0 (Vol. 2). en_US
dc.identifier.isbn 978-9975-64-458-7
dc.identifier.isbn 978 9975-64-460-0
dc.identifier.uri http://repository.utm.md/handle/5014/28013
dc.description.abstract At this time, there are many threats that lead to penetrating gunshot wounds that need to be promptly and effectively diagnosed, and that require a great deal of effort in the treatment process to preserve the patient's life and health. The problem is complicated by the fact that the formation of the wound channel depends on a large number of influencing factors: the type of bullet, speed, torque and other factors, which cannot be determined during the initial examination and diagnosis of patients. There are many methods of analyzing the behavior of a bullet when passing through a patient's body for the formation of general contaminations and the study of this phenomenon: including the use of ballistic stands-simulators of a biological object. The authors considered the possibility of providing such ballistic stands with a high-speed telemetric system for controlling the parameters of the experimental stand for studying the striking effect of penetrating wounds. en_US
dc.language.iso en en_US
dc.publisher Universitatea Tehnică a Moldovei en_US
dc.relation.ispartofseries Conferinţa tehnico-ştiinţifică a studenţilor, masteranzilor şi doctoranzilor = Technical Scientific Conference of Undergraduate, Master and PhD Students: Chişinău, 27-29 martie 2024. Vol. 2;
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject disaster surgery en_US
dc.subject penetrating wound en_US
dc.subject ballistic stand en_US
dc.subject telemetric parameter control system en_US
dc.title Telemetric system for monitoring the parameters of an experimental stand for tracking the damaging effects of penetrating wounds en_US
dc.type Article en_US