  • ABABII, I.; DIACOVA, S.; MANIUC, M.; ABABII, P.; DANILOV, L. (Technical University of Moldova, 2011)
    Several hundred children in the first year of life were evaluated and treated for a variety of diseases. Seven sets of measures were used in the study: 1. Background characteristics; 2. Otological questionnaires; 3. ...
  • DIACOVA, S. (Tehnica UTM, 2019)
    The purpose of this article is to determine the role of the noninvasive electro-acoustical examinations in treatment modality selection in prolonged otitis media forms. Impedance audiometry, brainstem evoked response ...
  • MONAICO, Eduard; URSAKI, Veaceslav; ZALAMAI, Victor; MASNIK, Alisa; SYRBU, Nicolae; BURLACU, Alexandru (Technical University of Moldova, 2011)
    We show that chalcopyrite CuInS2 crystals can be nanostructured by electrochemical treatment in an aqueous HCl solution. In order the crystals to become suitable for electrochemical nanostructuring they are subjected to ...
  • BARANOV, Serghei Alexei (Tehnica UTM, 2014)
    The kinetic model of electrochemical nucleation of micro- and nanoparticles is studied. The functional dependence of probability of the energy of the particle on the relative radius found earlier is used in nucleation in ...
  • TIGINYANU, I.M.; MONAICO, E.; URSAKI, V.V.; COLIBABA, G.; NEDEOGLO, D.D.; LEPORDA, N. (Technical University of Moldova, 2009)
    In this paper we demonstrate the possibility to control the conductivity of ZnSe in a degree acceptable for electrochemical nanostructuring. Technological methods for the preparation of nanostructures and composite materials ...
  • BODIUL, P.; SOROCHIN, S.; COTÎRŞEV, S.; CEBOTĂREANU, A.; ODAINÎII, G.; CEOBANU, S. (Technical University of Moldova, 2005)
    In the present paper two independent methods were used. By the field and temperature dependences of the phonon thermopower in the ultraquantum limit (UQL) and by the temperature dependence of the size-sensitive part of ...
  • YALTYCHENKO, O.V.; KANAROVSKII, E.Yu. (Tehnica UTM, 2014)
    In the given paper the minimal theoretical model for the description of kinetic processes in the organic nanocomposite material is offered. The subject of simulation is a three-center nanocluster embedded in an organic ...
  • OSTROVSKY, S.M.,; KLOKISHNER, S.I. (Universitatea Tehnică a Moldovei, 2021)
    A model for the description of the charge transfer induced spin transition in a crystal containing as a structural element cyanide-bridged binuclear Co-Fe clusters is presented. The cooperative interaction responsible for ...
  • RACZYŃSKI, M.; PRZENIOSŁO, Ł.; JAGUSZEWSK, M.; MIGUEZ, E. Martinez; JASKUŁA, M.; MATIAS, D.; BIEDKA, A.; MAKIEWICZ, P.; BIEGUN, M.; MIJOWSKA, E.; El FRAY, M.; PODOLSKI, J.; PENKALA, K. (Tehnica UTM, 2015)
    In the paper the results of research on electronic measurement and control systems designed for a multifunctional graphene-based biosensor are presented. Design of different types of biosensing electrodes based on graphene ...
  • SECRIERU, V.; DOROGAN, V.; VIERU, T.; VIERU, S.; MUNTEANU, E.; DOROGAN, A. (Tehnica UTM, 2014)
    The electronic device for measuring resilience of fibro-mucosa of protective field of the mouth contains the mobile probe and a displacement element, pressure sensor and amplifier circuit [1-3]. The control circuit is based ...
  • SMYSLOV, V.; YAKUNIN, V.; BELOTSERKOVSKII, I. (Technical University of Moldova, 2011)
    The TPH-485-0,06 submersible level transducer of hydrostatic pressure is a general-purpose sensor for measuring the level of fresh water or other mildly corrosive liquids. The TPH-485-0,06 submersible level transducer can ...
  • SMYSLOV, Vladimir; YAKUNIN, Vladimir; BELOTSERKOVSKII, Igori; YAKUNIN, Anton; VASEASHTA, Ashok (Tehnica UTM, 2013)
    The TP22E gage pressure and temperature transducer consists of a primary pressure transducer, fittings with an M20x1.5 standard connection to the measured medium and a built-in pressure modulus with a metal isolating ...
  • ABABII, Nicolai; CHIRIAC, Maxim (Universitatea Tehnică a Moldovei, 2023)
    Indicațiile metodice de față sunt destinate studenților programelor de studii Microelectronică și nanotehnologii și Electronica aplicată privind desfășurarea lucrărilor de laborator la cursul Electronica pentru automobile. ...
  • SERYAKOV, A.; SONTEA, V.; POCAZNOI, I.; BARUN, V. (Tehnica UTM, 2014)
    Reduction of the postoperative time, acceleration of wound healing, stimulating the regeneration processes, acceleration of wound healing - are questions that interested physicians all the time. In addition, patients would ...
  • BANU, S.; BOTNARIUC, V.; GORCEAC, L.; COVAL, A.; CINIC, B.; CHETRUŞ, P.; RAEVSCHI, S. (Tehnica UTM, 2013)
    The objective of this paper is establishing of the optimum conditions for CdS layers deposition by pulverization method on glass substrates coated with a previously deposited tampon SnO2 layer, studies of their electrical ...
  • GOLOVIN, Anatoly V. (Technical University of Moldova, 2011)
    In portable hand-held devices for trace explosive and narcotic detection the most perspective is use of a principle of ion mobility spectrometry owing to the best combination of cost, compactness, parameters of detection ...
  • ROZORYNOV, G.N.; AYMEN, Fendri Mohamed (Tehnica UTM, 2013)
    The basic requirements, produced to the electrostimulation apparatus, are considered. The economical mode of excitation of structures is determined during the leadthrough of electrostimulation. It is shown that it is ...
  • MORARU, Vasile (Universitatea Tehnică a Moldovei, 2009)
    În lucrare sunt prezentate principalele metode de calcul numeric pentru rezolvarea unor probleme ce pot fi întâlnite frecvent în practică. Ea se adresează în primul rând studenţilor Universităţii Tehnice a Moldovei şi va ...
  • CORCIOVĂ, Călin; ZAHARIA, Dan (Tehnica UTM, 2013)
    Medical equipment quality assurance is part of an overall medical equipment management program for a healthcare facility or system. A complete program includes corrective maintenance or repair, equipment control, asset ...
  • PENIN, Alexandr; SIDORENCO, Anatolie (Technical University of Moldova, 2011)
    Empirical linearly-hyperbolic approximation of the I-V characteristic of diodes and solar cell is presented. This approximation is based on hyperbolic dependence of a current of the p–n junctions on voltage for large ...