IRTUM – Institutional Repository of the Technical University of Moldova

Сonsolidarea și reabilitarea sediului Băncii Naționale a Moldovei

Show simple item record

dc.contributor.advisor COTOROBAI, Vasile
dc.contributor.author SAMOILĂ, Dinu
dc.date.accessioned 2021-02-09T09:28:06Z
dc.date.available 2021-02-09T09:28:06Z
dc.date.issued 2019
dc.identifier.citation SAMOILĂ, Dinu. Сonsolidarea și reabilitarea sediului Băncii Naționale a Moldovei: tz. de master: Programul de studiu: Inginerie Structurală. Cond. şt. COTOROBAI Vasile. Universitatea Tehnică a Moldovei. Chişinău, 2019. en_US
dc.identifier.uri http://repository.utm.md/handle/5014/12740
dc.description Fișierul atașat conține: Rezumat, Abstract, Cuprins, Introducere. en_US
dc.description.abstract Ca motiv pentru efectuarea tezei date a servit expertiza tehnică efectuată în 1996 de către exeperții tehnici Zolotcov și Izmailov.In care este expus următorul lucru,clădirea a fost calculată la un eventual seism de 7 baluri fără a se lua în calcul că în apropiere este situat edificiul ministerului finanțelor care este amplasat pe un teren cu seismicitatea de 8 baluri în urma efectuării cercetărilor geofizice a terenului care s-au efectuat după întocmirea hărții zonării seismice sa ajuns la concluzia că construcția se află pe teren cu seismicitatea de 8 baluri.Mi-am propus să examinez problema dată în vederea depistării soluției celei mai eficiente din punct de vedere economic. În capitolul 1 mi-am expus părerea despre mai multe metode de consolidare printre care se numără următoarele pentru grinzi: 1)Refacerea capacităţii portante a grinzilor fără modificarea schemei statice 2) Refacerea capacităţii portante a grinzilor prin modificarea gabaritului initial 3) Refacerea capacităţii portante a grinzilor prin modificarea schemei statice 4) Refacerea capacităţii portante prin sistemul grindă-macaz: montarea tiranţilor Pentru stîlpi: 1) Consolidarea cu beton turnat în cofraj 2) Beton torcretat 3) Utilizarea răşinilor în consolidări 4) Utilizarea armăturilor. Drept metodă de consolidare am ales consolidarea grinzilor prin intermediul tiranților macaz. Esența metodei precum și modalitatea de calcul a fost descrisă în capitolul 2 al lucrării date, pentru predimensionarea tiranților macaz putem utiliza mai multe metode precum metoda analitică sau prin intermediul programului aplicativ SCAD precum și prin intermediul softului matlab. În capitolul 3 am efectuat calculul structurii portante al clădirii și am depistat 21 de grinzi care au o subarmare nefavorabilă în cazul unui cutremur la fel cum și în expertiza efectuată de experți.Calculul l-am efectuat cu ajutorul softului SCAD.Pentru grinda de pe axa B am efectuat calculul tirantului de consolidare a grinzii la fel prin intermediul softului dat,în urma calculului am depistat secțiunea necesară a tirantului. en_US
dc.description.abstract The reason for this thesis was the technical expertise carried out in 1996 by the technical experts Zolotcov and Izmailov. In which the following is exposed, the building was calculated at a possible 7-ball seismic without taking into account that the edifice is located nearby the ministry of finance, which is located on a land with seismicity of 8 balls following the geophysical researches of the land that were done after the map of seismic zoning was concluded that the construction is on the field with seismicity of 8 balls. to examine the problem in order to find the most effective solution in this regard economically. In Chapter 1 I expressed my opinion about several consolidation methods, including the following for beams: 1) Restoration of the bearing capacity of the beams without modification of the static scheme 2) Restoration of the bearing capacity of the beams by modification of the initial gauge 3) Restoration of the carrying capacity of the beams of the beams by modifying the static scheme 4) Restoration of the bearing capacity through the beam-turn system:For pillars: 1) Reinforced concrete in formwork 2) Stirred concrete 3) Use of resins in reinforcements 4) Use of reinforcementsAs a consolidation method, we have chosen to strengthen the beams by means of the tie rod. The essence of this method as well as the method of calculation has been described in Chapter 2 of this paper, we can use several methods such as analytical method or through the SCAD application program as well as the matlab software.In chapter 3 we carried out the calculation of the load-bearing structure of the building and we found 21 beams that have an unfavorable underarm in the event of an earthquake as well as the experts' expertise. The calculation was carried out using the SCAD software. For the beam on the axis B we performed the calculation of the beam reinforcement tie also by means of the given software, following the calculation we found the necessary section of the strut.
dc.language.iso ro en_US
dc.publisher Universitatea Tehnică a Moldovei en_US
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject Bancă Națională en_US
dc.subject blocuri en_US
dc.subject nivele en_US
dc.subject zonă seismică en_US
dc.title Сonsolidarea și reabilitarea sediului Băncii Naționale a Moldovei en_US
dc.title.alternative Rehabilitation and consolidation of the National Bank of Moldova en_US
dc.type Thesis en_US


Files in this item

The following license files are associated with this item:

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 United States Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 United States

Search DSpace


Browse

My Account